After the maple sports floor is laid or heated in winter, when the floor heating system is used for the first time, it should be carried out at a slower speed. When the basic ground temperature rises to about 25°C, it should be maintained at a constant temperature for 12 to 24 hours, and then gradually increase to the required indoor temperature. The temperature should not be too high. The surface temperature of the maple sports floor should be less than or equal to 28°C.

Because if the temperature of the gym reaches above 30°C in a short period of time, the maple sports floor will not only lose heat energy, shorten the life of the geothermal system, and cause potential safety hazards, but also easily cause problems such as twisting, arching, and cracking of the floor.
In addition, after the maple sports floor is paved with geothermal heating, it is recommended to do environmental protection inspection to ensure that the free formaldehyde emission is qualified, so as to avoid health pollution.