Installation conditions for wooden floors in gymnasiums

Installation conditions for wooden floors in gymnasiums

A qualified gymnasium wood floor has high requirements for installation technology. Installing gymnasium wood floor looks rough, but in fact But it is meticulous work, how to ensure the gymnasium wooden floor bearing performance, sports performance, environmental adaptability, how to make athletes feel comfortable and safe when exercising on it, how to To make its surface friction coefficient meet the standard, these are all considerations in construction. Let's take a look at the installation conditions for the gym wooden floor.


1. General site conditions
The moisture content of the cement the wooden floor of the gymnasium should not exceed 5%, and the site conditions must be weatherproof. All wet work must be air-dried. The relative humidity of the air should be the same as predicted when the building is used, otherwise heating and/or extraction systems will be required. The difference between *low/*high relative humidity must never exceed 30%.
Sports wood flooring
2. General installation conditions
1. Platform: The unevenness should not exceed 2mm under the 1.5mm straight edge, otherwise the level must be adjusted with the appropriate material.
2. Waterproof membrane: The minimum 0.15mm polyethylene is lifted and pasted on the wall and 200mm lap is reserved at the lap joint.
3. Gym Flooring: Cut and lay the panels, providing expansion joints along the perimeter and for nets and other attachment points.
4. Allowable expansion and contraction: The width of each floor is reserved for 20mm shrinkage joints to ensure the shrinkage and expansion of the gymnasium wooden floor under the conditions of mechanics and air dry humidity.